[Home](/)/[Resources](/resources)/India CDSCO Medical Devices Registration

IndiaMedical Devices

# India CDSCO Medical Devices Registration: Classes, Licences, and the MD Rules 2017

India's medical device regulatory framework has matured significantly since the Medical Devices Rules 2017 came into force. If you are bringing a medical device to market in India — whether hardware, software, or combination — understanding the Class A-D system, the SUGAM portal, and the role of international approvals in your application is where to start.

Copy Link[Share on WhatsApp](https://wa.me/?text=https%3A%2F%2Fkrono-labs.com%2Fguides%2Findia-cdsco-medical-devices)

At a glance

Regulator

CDSCO (under Ministry of Health and Family Welfare)

Framework

Medical Devices Rules 2017

Classes

A (lowest risk) to D (highest risk)

Licence

Import Licence from CDSCO or State Licensing Authority

## India's medical device regulatory framework

### Medical device classification under MD Rules 2017

India uses a four-class risk-based classification system under the Medical Devices Rules 2017. Class A covers lowest-risk devices such as thermometers, bandages, and examination gloves. Class B includes low-to-moderate risk devices such as syringes, hypodermic needles, and electrodes. Class C covers moderate-to-high risk devices such as ventilators, blood glucose monitors, and dialysis equipment. Class D encompasses the highest-risk devices including pacemakers, implantable defibrillators, and coronary stents.

### Import Licence requirement

Any company importing medical devices into India must obtain a product-specific Import Licence from the appropriate regulatory authority before the device can clear customs and be placed on the market. For Class A and Class B devices, Import Licences are issued by State Licensing Authorities (SLAs) in the state where the importer's registered office is located. For Class C and Class D devices — which carry higher risk — the Import Licence is granted centrally by CDSCO's licensing authority in New Delhi.

### MD 14 Form and product registration via SUGAM

Regulated medical devices must be registered with CDSCO using the prescribed application forms (Form MD-14 for Import Licence). Applications are submitted through the SUGAM online portal (sugam.gov.in), which is the single digital interface for all medical device regulatory submissions in India. The SUGAM application requires the applicant to provide device description, intended use, risk classification justification, conformity assessment evidence, and quality management system details.

### Substantial equivalence and international regulatory evidence

India accepts regulatory evidence from predicate markets as part of the CDSCO registration process. A notarised copy of a valid US FDA 510(k) clearance, EU CE marking certificate (with Declaration of Conformity), or UK MHRA registration significantly strengthens and can accelerate an India application. CDSCO uses this evidence as part of its conformity assessment review but does not accept it as a direct substitute for the India registration process — a local application and licence are still required.

## Navigating the CDSCO registration process

01

Classify your medical device under India's Class A-D system using the risk classification criteria set out in Schedule I of the Medical Devices Rules 2017. Classification criteria include the intended purpose, duration of contact with the body, whether the device is invasive or active, and whether it delivers energy or substances to the patient. If uncertain, CDSCO guidance documents and classification databases are available on the CDSCO website; a regulatory affairs consultant with India experience can provide classification opinion for complex products.

02

Register on the SUGAM online portal (sugam.gov.in). Create a company account, select the applicable device category, and initiate the Import Licence application (Form MD-14). Ensure the company's Authorised Indian Representative (AIR) — a legal entity in India that accepts regulatory responsibility for the imported device — is identified and registered on SUGAM, as an AIR is mandatory for foreign manufacturers.

03

Prepare the technical documentation package: comprehensive device description and intended purpose; risk classification justification referencing Schedule I criteria; performance testing data and clinical evidence (literature-based or clinical investigation); labeling in English with all mandatory elements; ISO 13485 quality management system certificate; and overseas regulatory approval (US FDA, EU CE, or equivalent) if available. Documents must be in English or accompanied by certified English translations.

04

Submit the application and pay the applicable government fee through the SUGAM portal. Processing timelines vary significantly by device class: Class A and B applications handled by State Licensing Authorities may take 6 to 9 months; Class C and D applications reviewed by CDSCO centrally typically take 9 to 18 months. CDSCO may issue queries during the review — responses to queries should be submitted within the specified timeframe to avoid application lapse.

05

Once licensed, maintain ongoing post-market vigilance obligations. Serious adverse events involving the device must be reported to CDSCO within specified timelines (30 days for non-life-threatening events, immediately for events resulting in death or serious injury). Maintain records of complaints, adverse events, and corrective actions. Cooperate with CDSCO inspections of the manufacturing site or Indian importer's premises. Renew the Import Licence before expiry — licences are typically valid for three to five years.

## Frequently asked questions

### Is CE marking accepted for CDSCO medical device registration in India?

CE marking from a notified body (for Class IIa, IIb, and III devices under EU MDR) is accepted as supporting evidence in a CDSCO application and can strengthen the conformity assessment portion of the dossier. However, CE marking does not replace the India registration process. A separate CDSCO Import Licence must still be obtained for each device. CDSCO's review of the application — including the CE certificate, technical file summary, and clinical evidence — forms the basis of the India licensing decision.

### What is the difference between the State Licensing Authority and CDSCO for medical device imports?

India's Medical Devices Rules 2017 split licensing authority between the central regulator (CDSCO) and state-level authorities (SLAs) based on device risk class. Class A and Class B devices — which are lower risk — are licensed by the SLA of the state in which the Indian importer's registered office is located. Class C and Class D devices, being higher risk, are licensed centrally by CDSCO's licensing authority. For a product portfolio spanning multiple risk classes, a company may need to interact with both CDSCO and the relevant state authority.

### How long does CDSCO medical device registration take?

Processing times vary by device class and application completeness. Class A and B applications at State Licensing Authorities: typically 6 to 9 months from a complete application. Class C and D applications at CDSCO: typically 9 to 18 months, though complex or novel devices may take longer. Applications that receive CDSCO queries — which are common for higher-risk devices — are paused pending the response. Having overseas regulatory approvals (FDA, CE) and a complete, well-organised technical dossier are the most reliable ways to reduce delays.

### Does software as a medical device (SaMD) require CDSCO registration in India?

Yes. India's Medical Devices Rules 2017 include software that meets the definition of a medical device — software intended to be used, alone or in combination, for diagnosis, treatment, prevention, monitoring, or alleviation of a disease or condition. SaMD is classified using the same Class A-D risk framework based on the severity of the condition addressed and the significance of the information provided by the software. Standalone diagnostic AI software, clinical decision support tools, and remote monitoring software are all potentially subject to CDSCO registration depending on their intended use.

**Disclaimer:** Educational resource only. Regulatory requirements change and vary by product category. Consult an accredited test laboratory or qualified compliance engineer before making certification decisions.

🇮🇳 India roadmap for your product

Every standard, document, and test that applies — free, no account required.

See your free roadmap[

Want an expert to take your product through 🇮🇳 India compliance for you?

One consultant from Krono's compliance team takes your product from requirements to legal sale, with a fixed quote before any work starts.

See compliance services](/services)

Learn this properly

In-depth course that teaches the full process, not just this one answer.

[Start the course — $149](/courses/04-bis-certification-for-electronics)[Prefer to read? Get the book — $24.99](/books/04-bis-certification-for-electronics)

Related guides

*   [India WPC Type ApprovalIndia WPC type approval for wireless products: frequency allocation, ETA application through Saral Sanchar portal, import conditions, and debarment rules for non-compliant devices.](/guides/india-wpc-type-approval)
*   [India BIS ISI CertificationIndia BIS ISI mandatory certification: regulated product categories, BIS-recognised lab testing, factory audit, licence grant, and IS standard marking requirements.](/guides/india-bis-isi-mandatory-certification)
*   [Australia TGA Class I DevicesAustralia TGA Class I medical devices: ARTG inclusion by sponsor, Essential Principles self-assessment, ISO 13485 QMS expectations, and post-market adverse event reporting.](/guides/australia-tga-class-i-devices)
*   [India E-Waste EPR RulesIndia E-Waste (Management) Rules 2022: producer EPR obligations, CPCB-authorised PROs, collection targets, recycled content certificates, and penalties for non-compliance.](/guides/india-e-waste-epr-rules-2022)